Furnace Service and Repair Everett, Washington

If your heating system in Everett, WA is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in Everett, WA. C.M. Heating has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on C.M. Heating to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.


Diagnostic of gas furnace due to vibration noises. Found a limit switch installed correctly by another company. Screw out of alignment causing balancing issues with blower motor. Performed general maintenance. Found no other issues. Installed Air Scrubber system and honeywell 4" filter

Everett, WA
07-21-2017


Technician performed diagnostic and found failed blower motor. Replaced motor and capacitor, all operations normal at this time.

Everett, WA
09-28-2017


Technician Completed Diagnostic of Gas Furnace- limit switch was tripped. Reset. Checked all other components. Unit working well at this time. Replaced filter.

Everett, WA
09-28-2017


CONSULT

EVERETT, WA
05-12-2017


CONSULT

EVERETT, WA
05-12-2017


MAINT

EVERETT, WA
05-12-2017


DIAGNOSTIC OF GAS FURNACE. Williams wall furnace- burners is lighting however fan does not come on. Found failed fan limit control.

EVERETT, WA
06-14-2017


Technician performed diagnostic and replaced failed contactor on electric furnace. All operations normal. Completed Air Handler/ Electric Furnace Diagnsotic, Definite Purpose Contactor 1-Pole.

Everett, WA
09-28-2017


Technician Installed a new air scrubber to an existing gas furnace.

Everett, WA
11-13-2017


Technician performed a repair on a venting repair.

Everett, WA
11-01-2017


Technician performed a diagnostic on a Coleman electric gas furnace. FURNACE NOT PRODUCING HEAT DUE TO FAILED SEQUENCER. REPLACED SEQUENCER AND RUN CAPACITOR. ALL OPERATIONS NORMAL AT THIS TIME.

Everett, WA
11-21-2017


Technician performed a gas furnace diagnostic. GF Diag- Found Hot surface ignitor has failed (OL reading), replaced Ignitor. Unit is operational and is functioning well

Everett, WA
10-18-2017


Technician performed diagnosed electric furnace fan all ways running no heat. Fan switch inside furnace was on. Show homeowner and turned off switch fan will only turn on with call for heat. No heat issue was thermostat being wired to wrong terminal at the state. White wire was landed on Y. Rewired so white wire lands on correct terminal Wednesday. All operations normal at this time.

Everett, WA
09-29-2017


Technician found bad fan motor. Will need to Research part and call customer with estimate for replacement. Will need to complete maintenance on heat pump at time of Fan Repair. Will continue maintenance on unit after repair has been done.

Everett, WA
09-28-2017


Technician performed diagnostic and replaced outdoor fan motor.

Everett, WA
10-12-2017


Technician performed a diagnostic on a gas furnace. GF Diag- Unit was not going through sequence of operations, stopped before Ignitor would turn on. Got an OL reading for Ignitor so it was replaced, Unit still wouldn't finish sequence. Checked gas valve and received 24V although no gas flow. Bad gas valve, informed customer of total repairs and recommended upgrade of furnace. Consultation has been made for October 13 @9-12 window.

Everett, WA
10-12-2017


Technician performed a diagnostic on a gas furnace. Upon investigation, found the gas valve to be failing. Furnace would go through sequence of operations up until signal to allow gas flow. Valve is getting 24V however, no gas flow. Recommend replacement for further diagnosis.

Everett, WA
11-22-2017