Comfortmaker GNJ150N20D
Gas fireplace diagnostic. Found failed gas valve, which does not have an available replacement. Provided estimate for replacement.
Everett, WA
07-21-2017

Tempstar N4H336AKE
Performed full maintenance on furnace. Inspected all combustion components, run capacitor, circuit board, pressure switch, tested carbon monoxide. Found small obstruction in pressure switch tubing. Removed at no charge. Recommend annual maintenance in the future to prohibit future occurrences. Cleaned furnace cabinet interior. All operations normal at this time.
Everett, WA
07-21-2017

American Standard HVAC 4A6H5042A1000A Split Heat Pump
Installation of new American Standard heat pump and air handler. Includes 20 kw heat strip, Honeywell F300 Electronic Air Cleaner, Pro 8000 Thermostat, concrete fiber pad, labor, materials, duct testing and permits.
Everett, WA
07-21-2017

American Standard HVAC ADD1A060A9241A
Installation of new American Standard gas furnace, heat pump, and coil. Included concrete fiber pad, Honeywell F100 Air Cleaner and Pro 8000 Thermostat, labor, materials, duct testing, and permits
Everett, WA
07-21-2017

Rheem RGRL-07* 2 Stage Gas Furnace
STANDARD MAINTENANCE OF GAS FURNACE. ALL OPERATIONS NORMAL AT THIS TIME
Everett, WA
07-11-2017

Lennox CHP26-024-2PA
Unit off on high head pressure. Found bad fan motor on the outdoor unit and it's not dissipating Heat which is causing high pressure cut off. Will need to replace outdoor fan motor and capacitor for motor. Recommend maintenance on system after repairs are made. Unit will need a new filter filter is completely clogged causing disruption in air flow. Remove filter and left unit off at breaker.
Everett, WA
07-21-2017

CHP26-024-2PA
Found unit with pilot out, relit pilot, found thermocouple and thermopile are bad and need replacement. Replaced faulty component on gas fireplace. Unit operating normally after repair.

Everett, WA
08-09-2017

Kozy Heat Chaska Chaska
found leak in key valve in wall repaired leak, tested again for gas leaks, none found.
EVERETT, WA
08-09-2017

American Standard HVAC 4A6V8036A1000BA
Installation of new American Standard 18 SEER Inverter Heat Pump and Variable Speed Air Handler. Includes Honeywell F100 media filter, thermostat, labor, materials, duct testing, electrical, and permits.
Everett, WA
07-21-2017

Napoleon Fireplaces BGD36CFG Crystallo DV Gas Fireplace
Replacement of thermocouple and gas valve on Napoleon Gas Fireplace
Everett, WA
08-03-2017

York HVAC DRHQ0241
Performed blower wheel cleaning. Replaced blower capacitor.
Everett, WA
08-03-2017